E×haust analyzer | |||
Measuring objects | Measuring range | Permissible indication error | |
Absolute error | Relative error | ||
HC | (0~2,000)×10-6vol | ±4×10-6vol | ±3% |
(2,001~5,000)×10-6vol | -- | ±5% | |
(5,001~10,000)×10-6vol | -- | ±10% | |
CO | (0-10.00)×10-2vol | ±0.02×10-2vol | ±3% |
(10.01~16.00)×10-2vol | -- | ±5% | |
CO2 | (0~16)×10-2vol | ±0.3×10-2vol | ±3% |
(16.1~20)×10-2vol | -- | ±5% | |
NO | (0~4,000)×10-6vol | ±25×10-6vol | ±4% |
(4,001~5,000)×10-6vol | -- | ±8% | |
O2 | (0.0~25.0)×10-2vol | ±0.1×10-2vol | ±5% |
Note: the absolute error and relative error, one of the requirements to meet. | |||
Flow analyzer | |||
Sampling frequency | 2Hz | ||
Sampling frequency | (80~200)L/S | ||
Flow accuracy | Absolute error: 4L/s, Relative error: ±4%(FS) | ||
Measuring range of diluted oxygen | (5~22.5)×10-2vol | ||
Measuring accuracy of diluted oxygen | 0.1×10-2vol/±5% | ||
Resolution of diluted oxygen | Absolute error: ±0.5×10-2vol, Relative error: ±5%(Max) | ||
Mass resolution | HC | 0.01mg/s | |
CO2 | 1mg/s | ||
CO | 0.1 mg/s | ||
NO | 0.01mg/s |